SERVICESCONTACT US
        + 400-676-1966
      • ENRU
      • 三
      • Home Company Products
          Emissions Monitoring
          Flue Gas AnalyzerCEMSOn-site CEMS (UV-DOAS)VOCs Analyzer & System (FID)Online VOCs Monitoring System (PID)FTIR Analyzer & SystemTemperature, Pressure & Velocity MonitorDust MonitorHumidity Analyzer
          Air Quality & Industrial Park Monitoring
          Air Quality Monitoring SystemDynamic CalibratorZero Gas GeneratorMicro Air Quality Monitoring SystemAmbient Particulate Monitor (β Ray)Ambient Dust Monitor (Laser Scattering)Ambient VOCs AnalyzerEnrichment AnalyzerOpen-Path FTIR Gas Analyzer
          Water Quality & Waste Water Monitoring
          Water Quality & Waste Water AnalyzerSensorAuto Water Sampler
          Process Analysis & Safety
          In-situ Laser Gas AnalyzerExtractive Laser Gas AnalyzerOn-site CEMS (TDLAS)Hydrogen AnalyzerCalorific Value Analyzer
          Portable
          Portable Flue Gas AnalyzerPortable FTIR Gas AnalyzerPortable VOCs Gas AnalyzerPortable Laser Gas Analyzer
          Analysis Module
          UV-DOAS Analysis ModuleTDLAS Analysis Module
          Spare Parts
          Spare Parts
          Lab Equipment
          Lab Equipment
        Applications News
          Industry News
          Company News
        Downloads Contact Us
    • >Products > ZDO-02 Dissolved Oxygen/Temperature Sensor
      • ZDO-02 Dissolved Oxygen/Temperature Sensor
      • Product Overview
      • MessageEmail

        The ZDO-02 Dissolved Oxygen Sensor is a kind of intelligent dissolved oxygen (OD) electrode adopting RS485 communication interface and standard Modbus protocol. It can be widely applied to dissolved oxygen monitoring in sewage plants, waterworks, surface water, aquaculture and industries, etc.

      • Features

        • With corrosion resistant shell and IP68, applicable to all kinds of poor working conditions

        • Adopt Optical Method without replacing dissolved oxygen membrane and electrolyte; with features of short polarization time and fast response, the measure is almost unaffected by dirt and velocity

        • Small drift of electrode, direct calibration in the air, dispensing with zeroing

        • With built-in NTC22K temperature compensation, the accuracy can reach 0.1℃.

        • Use RS485 communication interface and standard Modbus protocol, convenient for integration



        Specifications   

        titleval
        PrincipleFluorescence Method
        Range0~20.00 mg/L
        Resolution0.01mg/L
        Repeatability±0.3mg/L
        Zero drift±0.1mg/L
        Span drift<45s            
        Measurement accuracy±0.3mg/L
        Response time±0.1mg/L
        Temp compensation accuracy±0.3mg/L
        Actual sample comparison±0.3mg/L
        Communication InterfaceRS485 (Modbus RTU standard protocol)
        DimensionD34mm, L205mm, cable of 3m (customizable)
        Working condition0℃~60℃ (no freezing), 0~4bar
        Working voltage12V/24V DC
        Voltage stability±±0.3mg/L
        Insulation resistance≥5MΩ
      • You May Also Like
    • Products Emissions Monitoring Air Quality & Industrial Park Monitoring Water Quality & Waste Water Monitoring Process Analysis & Safety Portable Analysis Module Spare Parts Lab Equipment
    • News Industry News Company News
    • Home Company Application Downloads
    • Contact Us Tel : +400-676-1966E-mail : export@zetian-tech.comAdd : No. 22 Zhiren Street, Binjiang District, Hangzhou, Zhejiang, China.
    • © 2002-2022 HangZhou Chunlai Technology Co.,Ltd. All rights reserved.
    XSubmit success!